430 research outputs found

    Whole breast radiotherapy in prone and supine position: is there a place for multi-beam IMRT?

    Get PDF
    Background: Early stage breast cancer patients are long-term survivors and finding techniques that may lower acute and late radiotherapy-induced toxicity is crucial. We compared dosimetry of wedged tangential fields (W-TF), tangential field intensity-modulated radiotherapy (TF-IMRT) and multi-beam IMRT (MB-IMRT) in prone and supine positions for whole-breast irradiation (WBI). Methods: MB-IMRT, TF-IMRT and W-TF treatment plans in prone and supine positions were generated for 18 unselected breast cancer patients. The median prescription dose to the optimized planning target volume (PTVoptim) was 50 Gy in 25 fractions. Dose-volume parameters and indices of conformity were calculated for the PTVoptim and organs-at-risk. Results: Prone MB-IMRT achieved (p= 600 cc heart dose was consistently lower in prone position; while for patients with smaller breasts heart dose metrics were comparable or worse compared to supine MB-IMRT. Doses to the contralateral breast were similar regardless of position or technique. Dosimetry of prone MB-IMRT and prone TF-IMRT differed slightly. Conclusions: MB-IMRT is the treatment of choice in supine position. Prone IMRT is superior to any supine treatment for right-sided breast cancer patients and left-sided breast cancer patients with larger breasts by obtaining better conformity indices, target dose distribution and sparing of the organs-at-risk. The influence of treatment techniques in prone position is less pronounced; moreover dosimetric differences between TF-IMRT and MB-IMRT are rather small

    Effect of radiation dose on the prevalence of apical periodontitis : a dosimetric analysis

    Get PDF
    Objectives : The objective of this study is to analyse the effect of the radiation dose of oral radiotherapy for cancer on the presence of apical periodontitis in patients without dental pre-screening or specific preventive measures. Materials and methods : All selected patients had been diagnosed with cancer in the head and neck region and presented in the dental clinic post radiotherapy with side effects (mainly radiation caries). The panoramic radiographs of these patients were examined for several parameters, including tooth decay and apical periodontitis. The total radiation dose per tooth was determined. Results : A total of 36 patient files were included, which accounted for 628 teeth to be scored. Tooth decay was present in 88.2% of teeth. Radiographic signs of apical periodontitis were found in 9.1% of the teeth. Teeth with apical periodontitis had significantly more caries present. The radiation dose was significantly higher for teeth with apical periodontitis (37.2 vs. 24.9 Gy). Binary logistic regression found the radiation dose to be the only explanatory variable in the presence of apical periodontitis. Conclusions : This study found that in zones with higher radiation dose, inflammation of the jawbone due to bacterial infection of the root canal is more likely to develop. This is probably due to bone changes post radiotherapy. Clinical relevance : An increase of this prevalance of apical periodontitis in irradiated bone found in this study needs to be taken into account in the dental evaluation before the start of radiotherapy

    Factors modifying the risk for developing acute skin toxicity after whole-breast intensity modulated radiotherapy

    Get PDF
    Background: After breast-conserving radiation therapy most patients experience acute skin toxicity to some degree. This may impair patients' quality of life, cause pain and discomfort. In this study, we investigated treatment and patient-related factors, including genetic polymorphisms, that can modify the risk for severe radiation-induced skin toxicity in breast cancer patients. Methods: We studied 377 patients treated at Ghent University Hospital and at ST.-Elisabeth Clinic and Maternity in Namur, with adjuvant intensity modulated radiotherapy (IMRT) after breast-conserving surgery for breast cancer. Women were treated in a prone or supine position with normofractionated (25 x 2 Gy) or hypofractionated (15 x 2.67 Gy) IMRT alone or in combination with other adjuvant therapies. Patient-and treatment-related factors and genetic markers in regulatory regions of radioresponsive genes and in LIG3, MLH1 and XRCC3 genes were considered as variables. Acute dermatitis was scored using the CTCAEv3.0 scoring system. Desquamation was scored separately on a 3-point scale (0-none, 1-dry, 2-moist). Results: Two-hundred and twenty patients (58%) developed G2+ dermatitis whereas moist desquamation occurred in 56 patients (15%). Normofractionation (both p = D (p = 0.001 and p = 0.043) and concurrent hormone therapy (p = 0.001 and p = 0.037) were significantly associated with occurrence of acute dermatitis and moist desquamation, respectively. Additional factors associated with an increased risk of acute dermatitis were the genetic variation in MLH1 rs1800734 (p=0.008), smoking during RT (p = 0.010) and supine IMRT (p = 0.004). Patients receiving trastuzumab showed decreased risk of acute dermatitis (p < 0.001). Conclusions: The normofractionation schedule, supine IMRT, concomitant hormone treatment and patient related factors (high BMI, large breast, smoking during treatment and the genetic variation in MLH1 rs1800734) were associated with increased acute skin toxicity in patients receiving radiation therapy after breast-conserving surgery. Trastuzumab seemed to be protective

    The relation between patient discomfort and uncompensated forces of a patient support device for breast and regional lymph node radiotherapy

    Get PDF
    Although many authors stated that a user-centred design approach in medical device development has added values, the most common research approach within healthcare is evidence-based medicine, which tend to focus on functional data rather than patient wellbeing and comfort. End user comfort is well addressed in literature for commercial products such as seats and hand tools but no data was found for medical devices. A commercial patient support device for breast radiotherapy was analysed and a relation was found between discomfort and uncompensated internal body forces. Derived from CT-images, simplified patient free-body diagrams were analysed and pain and comfort evaluated. Subsequently, a new patient position was established and prototypes were developed. Patient comfort- and prototype optimization was done through iterative prototyping. With this approach, we were able to compensate all internal body forces and establish a force neutral patient free-body diagram. This resulted in comfortable patient positioning and favourable medical results

    Early biomarkers related to secondary primary cancer risk in radiotherapy treated prostate cancer patients: IMRT versus IMAT

    Get PDF
    AbstractPurposeTo investigate whether rotational techniques (Volumetric Modulated Arc Therapy – VMAT) are associated with a higher risk for secondary primary malignancies compared to step-and-shoot Intensity Modulated Radiation Therapy (ss-IMRT). To this end, radiation therapy (RT) induced DNA double-strand-breaks and the resulting chromosomal damage were assessed in peripheral blood T-lymphocytes of prostate cancer (PCa) patients applying γH2AX foci and G0 micronucleus (MN) assays.Methods and materialsThe study comprised 33PCa patients. A blood sample was taken before start of therapy and after the 1st and 3rd RT fraction to determine respectively the RT-induced γH2AX foci and MN. The equivalent total body dose (DETB) was calculated based on treatment planning data.ResultsA linear dose response was obtained for γH2AX foci yields versus DETB while MN showed a linear-quadratic dose response. Patients treated with large volume (LV) VMAT show a significantly higher level of induced γH2AX foci and MN compared to IMRT and small volume (SV) VMAT (p<0.01). Assuming a linear-quadratic relationship, a satisfactory correlation was found between both endpoints (R2 0.86).ConclusionsBiomarker responses were governed by dose and irradiated volume of normal tissues. No significant differences between IMRT and rotational therapy inherent to the technique itself were observed

    Reproducibility of deep inspiration breath hold for prone left-sided whole breast irradiation

    Get PDF
    Background: Investigating reproducibility and instability of deep inspiration breath hold (DIBH) in the prone position to reduce heart dose for left-sided whole breast irradiation. Methods: Thirty patients were included and underwent 2 prone DIBH CT-scans during simulation. Overlap indices were calculated for the ipsilateral breast, heart and lungs to evaluate the anatomical reproducibility of the DIBH maneuver. The breathing motion of 21 patients treated with prone DIBH were registered using magnetic probes. These breathing curves were investigated to gain data on intra-fraction reproducibility and instability of the different DIBH cycles during treatment. Results: Overlap index was 0.98 for the ipsilateral breast and 0.96 for heart and both lungs between the 2 prone DIBH-scans. The magnetic sensors reported population amplitudes of 2.8 +/- 1.3 mm for shallow breathing and 11.7 +/- 4.7 mm for DIBH, an intra-fraction standard deviation of 1.0 +/- 0.4 mm for DIBH, an intra-breath hold instability of 1.0 +/- 0.6 mm and a treatment time of 300 +/- 69 s. Conclusion: Prone DIBH can be accurately clinically implemented with acceptable reproducibility and instability

    Potential benefits of crawl position for prone radiation therapy in breast cancer

    Get PDF
    Purpose: To investigate crawl position with the arm at the treated side alongside the body and at the opposite side above the head for prone treatment in patients requiring breast and regional lymph node irradiation. Methods: Patient support devices for crawl position were built for CT simulation and treatment. An asymmetric fork design resulted from an iterative process of prototype construction and testing. The fork's large horn supports the hemi-thorax, shoulder, and elevated arm at the nontreated side and the head. The short, narrow horn supports the arm at the treated side. Between both horns, the treated breast and its regional lymph nodes are exposed. Endpoints were pain, comfort, set-up precision, beam access to the breast and lymph nodes, and plan dose metrics. Pain and comfort were tested by volunteers (n = 9); set-up precision, beam access, and plan dose metrics were tested by means of a patient study (n = 10). The AIOTM (Orfit, Wijnegem, Belgium) prone breastboard (AIOTM) was used as a reference regarding comfort and set-up precision. Results: Pain at the sternum, the ipsilateral shoulder, upper arm, and neck was lower in crawl position than with bilateral arm elevation on AIOTM. Comfort and setup precision were better on the crawl prototype than on AIOTM. In crawl position, beam directions in the coronal and near-sagittal planes have access to the breast or regional lymph nodes without traversing device components. Plan comparison between supine and crawl positions showed better dose homogeneity for the breast and lymph node targets and dose reductions to all organs at risk for crawl position. Conclusions: Radiation therapy for breast and regional lymph nodes in crawl position is feasible. Good comfort and set-up precision were demonstrated. Planning results support the hypothesis that breast and regional lymph nodes can be treated in crawl position with less dose to organs at risk and equal or better dose distribution in the target volumes than in supine position. The crawl technique is a candidate methodology for further investigation for patients requiring breast and regional lymph node irradiation

    The effect of morphometric atlas selection on multi-atlas-based automatic brachial plexus segmentation

    Get PDF
    Purpose: The present study aimed to measure the effect of a morphometric atlas selection strategy on the accuracy of multi-atlas-based BP autosegmentation using the commercially available software package ADMIRE (R) and to determine the optimal number of selected atlases to use. Autosegmentation accuracy was measured by comparing all generated automatic BP segmentations with anatomically validated gold standard segmentations that were developed using cadavers. Materials and methods: Twelve cadaver computed tomography (CT) atlases were included in the study. One atlas was selected as a patient in ADMIRE (R), and multi-atlas-based BP autosegmentation was first performed with a group of morphometrically preselected atlases. In this group, the atlases were selected on the basis of similarity in the shoulder protraction position with the patient. The number of selected atlases used started at two and increased up to eight. Subsequently, a group of randomly chosen, non-selected atlases were taken. In this second group, every possible combination of 2 to 8 random atlases was used for multi-atlas-based BP autosegmentation. For both groups, the average Dice similarity coefficient (DSC), Jaccard index (JI) and Inclusion index (INI) were calculated, measuring the similarity of the generated automatic BP segmentations and the gold standard segmentation. Similarity indices of both groups were compared using an independent sample t-test, and the optimal number of selected atlases was investigated using an equivalence trial. Results: For each number of atlases, average similarity indices of the morphometrically selected atlas group were significantly higher than the random group (p<0,05). In this study, the highest similarity indices were achieved using multi-atlas autosegmentation with 6 selected atlases (average DSC = 0,598; average JI = 0,434; average INI = 0,733). Conclusions: Morphometric atlas selection on the basis of the protraction position of the patient significantly improves multi-atlas-based BP autosegmentation accuracy. In this study, the optimal number of selected atlases used was six, but for definitive conclusions about the optimal number of atlases and to improve the autosegmentation accuracy for clinical use, more atlases need to be included
    • …
    corecore